FLUKE-115

Rp4.972.500

4 in stock

Swahusada is the official distributor of Fluke in Indonesia. All items on this website are new, and have a direct factory warranty. If you need another type, you can chat with us directly.
We serve pre-order and indent purchases for all Fluke units, Fluke Process Instrument, and Fluke Network., and Fluke Calibration.

Fluke 115/EM ESP Field Service Technicians Multimeter

Key features :

  • Compact True-rms digital multimeter for field service
  • Includes: meter, holster, 4 mm PVC-Insulated test lead
  • Easy one-handed operation of the meter
  • Min/Max/Average to record signal fluctuations
Specifications
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy± ([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS
(45 Hz to 500Hz)
Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A overload for 30-seconds max
DC ampsRange/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2Range/resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.

Cek Ongkir