FLUKE 17B-MAX-01

Rp2.718.300

19 in stock

Swahusada is the official distributor of Fluke in Indonesia. All items on this website are new, and have a direct factory warranty. If you need another type, you can chat with us directly.
We serve pre-order and indent purchases for all Fluke units, Fluke Process Instrument, and Fluke Network., and Fluke Calibration.

Fluke 17B MAX 01 Digital Multimeter

Includes:

  • TL75 Test Leads with 2 Protective Caps
  • Type K Thermocouple
  • 2 AA Batteries
  • Safety information

Fluke 15B MAX Inherits and continues the classic design of 15B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.

Key features :

  • Audible and visual alarm for incorrect connections
  • Test leads with fines tips for circuit board testing
  • Simple interface to wake meter from sleep mode by activating any buttons
  • Voltage: 6000-count reading
  • Capacitance range: 2000uF
  • Safety rating: CATIII 600V
  • Frequency and temperature measurement
FunctionRangeResolutionAccuracy
AC Volts (40 Hz to 500 Hz)16.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
AC Millivolts600.0 mV0.1 mV3.0 % + 3
DC Volts6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3
DC Millivolts600.0 mV0.1 mV1.0 % + 10
AC Current μA (40 Hz to 400 Hz)2400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
AC Current mA (40 Hz to 400 Hz)240.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
AC Current A (40 Hz to 400 Hz)24.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC Current μA2400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
DC Current mA240.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
DC Current A24.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
Diode Test32.000 V0.001 V10%
Temperature 450.0 °C to 400.0 °C
0 °C to 50.0 °C
-55.0 °C to 0 °C
0.1 °C2 %+1 °C
2 °C
9 %+2 °C
Resistance (Ohms)5400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance640.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
2000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1 (10 Hz to 100 kHz)50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty Cycle11% to 99%0.10%1 % typical7
Continuity Threshold70Ω
BacklightYes
1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
4Use Type K thermocouple
5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.

Cek Ongkir