Fluke 319 Clamp Meter

The Fluke 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.

Key features :
-Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
-The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
-The large backlight display facilitates readings in dark environments
-Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example. (319)
-Current frequency measurement
-Precision down to 0.01A and 0.1V
-1000A/600A AC/DC current measurement (319/317)
-600V AC/DC voltage measurement
-4000Ω resistance measurement
-Continuity beeper
-Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
-One year warranty

319 Electrical specifications
Current ACRange40.00 A, 600.0 A, 1000 A
Resolution0.01 A, 0.1 A, 1 A
Accuracy1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 23.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC responserms
Current DCRange40.00 A, 600.0 A, 1000 A
Resolution0.01 A, 0.1 A, 1 A
Accuracy1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
Voltage ACRange600.0 V
Resolution0.1 V
Accuracy1.5% ±5 digit (20-500Hz)
AC responserms
Voltage DCRange600.0 V
Resolution0.1 V
Accuracy1% ±4 digit
ResistanceRange400.0 Ω
4000 Ω
Resolution0.1 Ω
1 Ω
Accuracy1% ±5 digit
Continuity≤ 30 Ω
InrushIntegration time100 ms
FrequencyRange5.0 – 500.0 Hz
Accuracy0.5% ±5 digit
Trigger Level10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
True rms for ac V and ac A accuracy is specified from 5% to 100% of range.